Hohmann & Barnard 2023 Product Catalog

HOHMANN & BARNARD, INC

MATERIAL CONFORMANCE

WIRE MATERIALS: Carbon steel wire: ASTM A1064/A1064M (Tensile Strength - 80,000 psi) Steel wire for masonry joint reinforcement: ASTM A951/A951M, TMS 402/602 (Building Code for Masonry Structures)

SHEET STEEL ITEMS MATERIALS: Carbon Steel Sheets: ASTM A1008/A1008M

FINISHES:

Mill Galvanized: ASTM A653/A653M Class G60 (0.6 oz/ft2) Hot-Dip Galvanized: ASTM A153/A153M-B2 (1.5 oz/ft2) Stainless Steel: ASTM A666, ASTM A480/A480M, andASTM A240/A240M – AISI Type 304 (316 on special order) Hohmann & Barnard recommends using type 304 or 316 Stainless Steel in all building projects to protect against corrosion and limit thermal transfer in the wall cavity. Please visit www.h-b.com for the most up to date technical information.

FINISHES:

Mill Galvanized: ASTM A641/A641M (0.1 oz/ft2) ASTM A641/A641M (0.4 oz/ft2) and ASTM A641/A641M (0.8 oz/ft2) available on special order Hot-Dip Galvanized: ASTM A153/A153M-B2 (1.5 oz/ft2) Stainless Steel: ASTM A580/A580M - AISI Type 304 (316 on special order)

DIAMETER: 9 Gauge (.148” or W1.7) 3/16” (.187” or W2.8)

Effective Steel Area (in 2 )

4” wall

6” wall

8" wall

10” wall

12” wall

14” wall

16” wall

#120 Truss

Standard - 9ga. S/R x 9ga. C/R

.051 .073

.050 .072

.048 .070

.047 .069

.045 .067

.044 .066

.043 .065

Super Heavy Duty - 3/16” S/R x 3/16” C/R

#220 Ladder

Standard - 9ga. S/R x 9ga. C/R

.0345 .0554

.0345 .0554

.0345 .0554

.0345 .0554

.0345 .0554

.0345 .0554

.0345 .0554

Super Heavy Duty - 3/16” S/R x 3/16” C/R

IMPORTANT: Since each construction project is unique, the appropriate selection and use of any product contained herein must be determined by competent architects, engineers and other appropriate professionals who are familiar with the specific requirements of the project in question. This catalog is intended as a design aid for use in North America, and on projects world-wide where North American design parameters have been used. The information in this catalog is provided in good faith. However, anchor and tie adequacy can be adversely affected by on-site workmanship and varying conditions in different geographic locations for which Hohmann & Barnard can accept no responsibility. Similarly, should Hohmann & Barnard products be used in conjunction with channels or components from other manufacturers, there can be no guarantee of performance. All application illustrations shown in the catalog are for guidance only and should not be taken as working drawings. Hohmann & Barnard reserves the right to amend, withdraw or to make changes to products and specifications at anytime without written notice to customers, designers and users. It is the policy of Hohmann & Barnard to work with designers, engineers and contractors in providing suggestions and advice for the satisfactory solution of anchoring problems. However, all advice and drawings provided are subject to the approval of the design team, contractor and structural engineer, who take ultimate responsibility for proper product usage.