Hohmann & Barnard 2023 Product Catalog

SHARKTOOTH & CSH INSERTS

Working Loads: Single Point Loading

Spacing Between Studs

Allowable Loads Ultimate Loads Tension Shear Tension Shear

Part Number

Insert Length*

ST-3

3”

N/A 5300# 5185# 10,600# 10,370#

ST-4

4”

N/A 5300# 5185# 10,600# 10,370#

ST-6

6”

4”

7889# 8059# 13,432# 20,147#

ST-8

8”

4”

7889# 8059# 13,432# 20,147#

ST-12

12”

4”

7889# 8059# 13,432# 20,147#

ST-24

24”

4”

7889# 8059# 13,432# 20,147#

ST-C 7889# 8059# 13,432# 20,147# * ST-C standard length is 12 ft. Other lengths available on special order. 12’ * 4”

Working Loads: Multiple Point Loading

- Shear controlled by flange bending. - Tension controlled by headed stud strengths.

Minimum Spacing Between Load

Allowable Loads

Part Number

Insert Length

Tension Shear

ST-12

12”

5”

4525# 8059#

ST-24

24’

5”

4525# 8059#

ST-C 12’-0”

6”

5300# 8059#

- Concrete strength = 4,000 p.s.i. - No additional reinforcement in the concrete has been assumed in the analysis of the sharktooth inserts. - Headed welded studs utilize a design factor of 2:1, as per manufacturers recommendations. - Insert #ST-3 and #ST-4 allowable shear loads and tension loads are controlled by headed stud strengths. - Insert #ST-6 thru #ST-C working tension and working shear loads controlled by insert flange bending. - Combined loading evaluation using;

)

(

) ( / * +

/ *

V actual V allowable

T actual T allowable

≤ 1.0

* or as required by code

- Allowable loads shown are applicable along the entire length of insert, no minimum distance required. - Minimum edge distance to centerline of headed stud equals 3-1/4” (vertical installation). - Minimum concrete required above or below centerline of headed studs, when mounted vertically or horizontally is 3-1/4”. - Higher allowable loads can be achieved for the #ST-3 or #ST-4 insert by increasing headed stud diameter. Patents pending.

27

For material conformances, submittal sheets, CAD drawings and SDS sheets visit: www.h-b.com